3S-2IS

Dual Orientations Irradiance Sensor

This Irradiance Sensor Model’s designation is 3S-2IS. It is specially developed to calculate the Performance Ratio (PR) for the dual orientation PV plants, as it calculates the average irradiance value as per the number of panels in each direction. Installation directions of panels in PV power plants and the number of panels in these directions may be different. The user will be able to set the number of panels in each orientation for the correct calculations. 3S-2IS special design allows simultaneous connection of two Irradiance Sensors, two Module Temperature Sensors, an Ambient Temperature Sensor, and a Wind Speed Sensor. The number of panels in both directions, to which the sensors are connected, is entered into the electronic card via 3S-2IS Configuration Interface. The total effective irradiance and total effective module temperature can be calculated and communicated to the datalogger via Modbus RTU protocol. By using these values, the accurate Performance Ratio can be calculated in the monitoring systems.

Description

3S-2IS – Dual Orientation Irradiance Sensor

The 3S-2IS is a high-precision irradiance sensor designed for dual-orientation PV plants. It calculates average irradiance based on the number of panels in each orientation, enabling accurate Performance Ratio (PR) calculations. Users can set the number of panels per orientation for precise results.

Key Features:

  • Reference Cell: Monocrystalline silicon (31 mm x 31 mm)

  • Irradiance Range: 0–1600 W/m²

  • Uncertainty: ≤1.2% (Class A, IEC61724-1)

  • Resolution: 0.1 W/m²

  • Response Time: 1 second

  • Field of View: >160°

  • Tilt-Azimuth Accuracy: ≤1°

  • Drift: <0.3% per year

  • Data Output: RS485, Modbus RTU, 1 reading/sec

  • Power Supply: 12–30 V DC | Power Consumption: 25 mA max @24 V DC

  • Operating Range: -40°C to +85°C, 0–100% RH

  • Sensor Housing: Aluminum, IP54 (IP65/IP68 optional)

  • Reference Cell Dimensions: 140 × 110 × 42 mm | Weight: 0.3 kg

  • Connected Sensors: Supports two module temperature sensors, one ambient temperature sensor, and one wind speed sensor

  • Calibration: Class AAA Sun Simulator as per IEC 60904-2 & IEC 60904-4

Functionality:
The 3S-2IS calculates total effective irradiance and module temperature from connected sensors, sending the data to a datalogger via Modbus RTU. This enables accurate Performance Ratio monitoring in PV plants with multiple panel orientations.